Official Manufacturing Certificates & Technical Compliance
Direct factory accreditation for overseas commercial builders, architects, and facade contractors. Verified third-party licences for North American NFRC, Australian AS 2047 & AS/NZS 2208, ISO 9001:2015, and global green building EPD® / FSC® standards.
NFRC Product Certificate of Authorization (CPD: ESD-M-1)
Official authorization from the National Fenestration Rating Council (NFRC). Validated under NFRC 100/102/200/500 simulation and physical testing by SATI and TATI test laboratories. Engineered for compliance with US IECC energy codes and ASHRAE 90.1 envelope standards.
ES70 Certified Performance Matrix
NFRC Certified Thermal & Solar Heat Gain Matrix (ES70 System)
Extracted directly from NFRC Authorization Schedule CPD: ESD-M-1. Physical testing conducted in accordance with NFRC 102 thermal chamber apparatus:
| System Model | Operator Type | U-Factor (US) | Equivalent SI (W/m²·K) | SHGC | Visible Light (VT) | Test Lab & Report | US Building Code Compliance |
|---|---|---|---|---|---|---|---|
| ES70 System (Option A) | Dual Action Tilt & Turn (DATT) | 0.24 BTU/(hr·ft²·°F) | 1.36 W/(m²·K) | 0.42 | 0.50 | TATI Q1367.01 / SATI Q1366 | US IECC Climate Zones 1-7, Energy Star Northern & North-Central |
| ES70 System (Option B) | Dual Action Tilt & Turn (DATT) | 0.27 BTU/(hr·ft²·°F) | 1.53 W/(m²·K) | 0.47 | 0.58 | TATI Q1367.01 / SATI Q1366 | US IECC Climate Zones 1-5, Commercial envelope compliance |
Australian Standards AS 2047 & AS/NZS 2208 Licences
Mandatory performance testing for external windows and doors entering Australia and New Zealand. Verified third-party accreditation by Intertek SAI Global and CSi under the JAS-ANZ scheme.
AS 2047-2014 Licence
AS 2047 Tested Models
AS/NZS 2208:1996 Glass
Official AS 2047-2014 Physical Test Performance Table
Extracted directly from StandardsMark Schedule SMK41678. Tested by NATA-accredited test laboratory apparatus in accordance with AS 4420 methods:
| Model ID | System Type | Maximum Size (H × W) | SLS Design Wind (Pa) | ULS Structural Wind (Pa) | Water Penetration (Pa) | Air Infiltration | NCC / AS 4055 Wind Suitability |
|---|---|---|---|---|---|---|---|
| MD75S | Tilt and Turn Window / Architectural Aluminium Window | 1800mm H × 1200mm W | 1600 Pa | 4000 Pa | 600 Pa | Low | Non-cyclonic N1 to N5, Cyclonic C1 to C2; High-rise exposed coastal |
| MD76A | Awning Window + Fixed Lite Combination | 1500mm H × 1800mm W | 800 Pa | 3000 Pa | 200 Pa | Low | Residential N1 to N3; Suburban residential & multi-unit townhouses |
National Quality Inspection Center Physical Test Reports (GB/T 7106 · GB/T 8484 · GB/T 8485)
Official laboratory physical performance testing issued by the National Quality Inspection and Testing Center for Aluminum Alloy Profiles, Doors and Windows (国家铝型材及门窗制品质量检验检测中心). Rigorously tested under GB/T 7106-2019 (air, water, wind load), GB/T 8484-2020 (thermal transmittance K ≤ 2.0 W/m²·K), and GB/T 8485-2008 (acoustic sound attenuation Rw ≥ 35 dB). Delivering verified Class 9 wind resistance (5000 Pa / ±5.0 kPa) for hurricane and coastal high-rise engineering.
CY112 Side-Pressure Integrated Window
US110 Slim Dual-Inward Window
Certified Engineering Test Performance Table (5 Architectural Window Series)
Verified laboratory results for JZZ1 engineered window lines tested in full configuration with double-glazed low-E insulated glass units (IGU) and multi-cavity thermal break extrusions:
| System Series | Frame Depth | Tested Dimensions | Wind Load (GB/T 7106) | Water Tightness | Air Permeability | Thermal U/K (W/m²·K) | Acoustic Rw |
|---|---|---|---|---|---|---|---|
| CY112 Side-Pressure | 112 mm | 1470 × 1470 mm | Class 9 (±5.0 kPa / 5000 Pa) | Class 6 (700 Pa) | Class 8 (q₁ = 0.31 / 0.28) | Class 8 (K = 1.4) | Class 4 (35 dB) |
| US110 Dual Inward | 110 mm | 1450 × 1450 mm | Class 9 (±5.0 kPa / 5000 Pa) | Class 6 (700 Pa) | Class 8 (q₁ = 0.22 / 0.23) | Class 9 (K = 1.2) | Class 4 (37 dB) |
| H1 Dual Inward | 110 mm | 1450 × 1450 mm | Class 9 (±5.0 kPa / 5000 Pa) | Class 6 (700 Pa) | Class 8 (q₁ = 0.28 / 0.22) | Class 8 (K = 1.3) | Class 4 (36 dB) |
| UC90 Inward Casement | 90 mm | 1450 × 1450 mm | Class 9 (±5.0 kPa / 5000 Pa) | Class 6 (700 Pa) | Class 8 (q₁ = 0.14 / 0.10) | Class 8 (K = 1.3) | Class 4 (36 dB) |
| WS110 Outward Integrated | 110 mm | 1450 × 1450 mm | Class 9 (±5.0 kPa / 5000 Pa) | Class 6 (700 Pa) | Class 8 (q₁ = 0.29 / 0.27) | Class 8 (K = 1.4) | Class 4 (35 dB) |
ISO 9001:2015 Quality Management System Certification
Verified factory quality assurance accredited by CNAS (China National Accreditation Service, Reg: C217-M) and recognized worldwide through the IAF Multilateral Recognition Arrangement (IAF MLA). Covers precision aluminum extrusion, thermal barrier profile fabrication, CNC machining, and architectural window assembly.
ISO 9001:2015 Certificate
ISO 9001:2015 认证原件
AkzoNobel® Powder Coatings & PPG® Architectural E-Coat Accreditations
Upstream material verification for architectural surface coatings applied across JZZ1 aluminum profiles, curtain wall mullions, and outdoor perimeter systems. Featuring AkzoNobel Interpon certified under LRQA ISO 9001 / ISO 14001 / ISO 45001 and IATF 16949:2016 automotive-grade quality standards, alongside PPG Cationic Epoxy E-Coat material safety compliance (SDS).
AkzoNobel® ISO Triple Cert
AkzoNobel® IATF 16949
阿克苏诺贝尔 IATF 认证
PPG® Cationic E-Coat
Architectural Surface Treatment & Salt Spray Resistance Matrix
Comparative performance standards for architectural surface finishes supplied on JZZ1 aluminum extrusions, curtain walls, and outdoor boundary systems:
| Coating Technology | Brand & System | Salt Spray Test (ASTM B117) | UV Weathering Standard | Adhesion (ASTM D3359) | Recommended Project Environment |
|---|---|---|---|---|---|
| Super Durable Powder Coating | AkzoNobel Interpon D2000 (Class 2) | > 1500 Hours | AAMA 2604 / Qualicoat Class 2 (5-yr Florida) | Class 5B Cross-Hatch (Zero peel) | High-rise residential, commercial office facades, suburban villas |
| Hyper Durable Fluorocarbon (PVDF) | AkzoNobel Interpon D3000 / 70% Kynar 500 | > 4000 Hours | AAMA 2605 (10-yr Florida South exposure) | Class 5B Cross-Hatch (Zero peel) | Exposed coastal, commercial curtain walls, airport and tropical towers |
| Cationic Epoxy E-Coat (Electrophoresis) | PPG Powercron® Cationic Epoxy (CP525D/CR682) | > 2000 Hours | Uniform electrodeposition without pinholes or edge gaps | Cross-hatch pass over phosphate pretreat | High-humidity tropical regions, seaside balcony railings, marine gates |
EPD® Environmental Product Declaration, FSC® & Intertek Testing
Verified sustainable building solutions for architectural facade louvers, composite exterior decking, and garden railing structures. Designed for developers and architects targeting LEED, BREEAM, and Green Star carbon reduction credits.
EPD® Product Declaration
FSC® Certified Sourcing
Intertek Physical & Fire Test
Metal Guardrails & Doors
CE & UKCA Mark Compliance
For European and UK commercial distribution, facade products require alignment with EN 14351-1 (Windows and external pedestrian doorsets) and Factory Production Control (FPC).
- EN 12210 Wind Load Resistance: Class C3 / C4 / C5 options
- EN 12208 Water Tightness: Up to Class 9A (600 Pa)
- EN 12207 Air Permeability: Class 4 highest airtightness
- EN 10077 Thermal Performance: U-values down to 1.1 W/(m²·K) with warm-edge IGUs
ASTM & AAMA Testing Standards
Commercial sourcing for the United States and Canada pairs NFRC thermal authorization with structural resilience (ASTM E330 & Florida Impact protocols).
- NFRC 100/200: U-factor, SHGC, and Visible Transmittance certified under CPD ESD-M-1
- ASTM E330: Structural performance under uniform static air pressure difference
- ASTM E283 / E331: Air leakage and water penetration laboratory simulation
- AAMA 2605: Superior performing 70% PVDF fluoropolymer architectural coating
Why certificate requests often get delayed
- The country is named, but the specific standard or building code edition is missing
- The buyer requests compliance before the window system (sliding vs tilt-turn) is chosen
- Glass thickness, interlayer, or hardware specifications are still fluctuating
- The certifier needs Form 15 / Form 16 format, but only headline prices were shared
- Mixed packages (e.g. windows, balustrades, gates) are grouped under one single standard
What speeds up compliance confirmation
- Identify target standard: e.g. NFRC 100/102, AS 2047-2014, AS/NZS 2208, or BCA SS 341
- Share the architectural window schedule or elevation PDF
- Specify wind region or design pressure (e.g. N3, ULS 3000 Pa, or coastal exposure)
- State whether certifier requires test report copy, factory declaration, or sample unit
- Confirm glass build-up early (e.g. 6mm Toughened + 12Ar + 6mm Toughened Low-E)
Frequently Asked Questions on International Certification
How does NFRC certification benefit US commercial and residential projects?
NFRC certification provides independent, standardized energy performance metrics required by the International Energy Conservation Code (IECC) and local building departments across the United States. JZZ1's ES70 system under CPD ESD-M-1 delivers certified U-factors of 0.24 to 0.27 and SHGC of 0.42 to 0.47, qualifying for Energy Star rebates and LEED envelope compliance without costly secondary simulations.
How does AS 2047 certification work for imported windows in Australia?
Under the National Construction Code (NCC), windows and glazed doors must comply with AS 2047. Rather than one-off test claims, JZZ1 holds StandardsMark Licence SMK41678 from Intertek SAI Global, which includes ongoing factory quality audits, full traceability, and verified NATA test reports for certified models like MD75S and MD76A.
Does JZZ1 provide AS/NZS 2208 glass stamps and certification?
Yes. Every piece of architectural safety glass installed in our export systems carries the permanent AS/NZS 2208 compliance bug/stamp detailing the standard, licence number, and glass type (toughened or laminated), backed by CSi Licence 7632.
Are JZZ1 manufacturing plants ISO 9001:2015 certified?
Yes. All manufacturing lines operate under ISO 9001:2015 Quality Management Systems (Certificate No. 39726Q00006R001), accredited by CNAS under the IAF MLA framework. This guarantees complete traceability from raw 6063-T5 aluminum billet casting through CNC profile fabrication, surface treatment, and window sealing.
Can JZZ1 provide EPD declarations and FSC certificates for green building credits?
Yes. JZZ1 provides third-party verified EPD declarations (Registration S-P-10194 under ISO 14025 / EN 15804) and FSC Chain of Custody documentation (Code GFA-COC-007174) for outdoor systems, decking, and architectural composite claddings, directly qualifying for LEED Material & Resources and BREEAM life cycle assessment credits.